1. White Spots and Rough Film Surface
Causes:- Poor dispersion of the filler due to low-quality production or incompatible processing equipment.
- Filler resin base not matching the main polymer used in the final film.
- Product deterioration caused by long storage time or improper handling conditions.
2. “Fish Eyes” or Bubbles on the Film Surface
Causes:- Excessive moisture in filler or recycled resin.
3. Poor Film Gloss
Causes:- Inappropriate calcium carbonate particle size or surface coating.
- Non-optimized formulation leading to poor surface finish.
4. Unstable Bubble or Film Vibration During Blowing
Causes:- The melt flow index (MFI) of the filler masterbatch does not match the resin matrix.
- Inconsistent or unstable air flow during the blowing process.
5. Low Film Strength or Poor Elongation
Causes:- Incompatible filler resin or excessive filler loading.
- Customer’s formulation not optimized for performance.
- Improper air flow or cooling speed in the film blowing process.
6. Film Breakage During Production
Causes:- Poor filler dispersion or contamination in the mixture.
- Inappropriate particle size of CaCO₃.
- Blocked filter screens reducing material flow.
7. Film Too White or Too Dark
Causes:- Excessive whiteness caused by high TiO₂ content or ultra-white calcium carbonate.
- Low-quality filler resulting in a dull or grayish tone.
- Incompatible resin base leading to poor color consistency.